Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C0507
Calculite
®
Evolution Incandescent Lensed Wall Washer C6P38L
Page 2 of 2 6" Aperture PAR38 Reflector Trim
876
54321
Perspec. Drawing Nos.
Calculite Evolution
Lighting Data
EXAMPLE: With multiple 120W PAR38 WFL units located
2’ from wall and 3’ on center, the illumination on the
wall 3’ down from the ceiling is 29 f.c. beneath and
24 f.c. between fixtures.
Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than
those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.
3’
2’
3’
35 f.c.
38 f.c.
Footcandles on Wall From Multiple Units - 120W PAR38 WFL
Conversion Factors:
90W PAR38 WFL: F.C. x 0.70
75W PAR38 WFL: F.C. x 0.55
60W PAR38 WFL: F.C. x 0.45
2’ 3’
1’ 39 39 39 32 19 32
2’ 56 53 56 42 31 42
3’ 49 49 49 35 38 35
4’ 35 35 35 24 23 24
5’ 24 25 24 17 17 17
6’ 17 18 17 12 12 12
7’ 13 13 13 9 9 9
8’ 9 10 9 7 7 7
9’ 7 7 7 5 6 5
3’ 4’
1’ 13 11 13 12 7 12
2’ 21 20 21 17 14 17
3’ 25 24 25 20 16 20
4’ 24 24 24 19 17 19
5’ 20 20 20 16 15 16
6’ 16 16 16 12 12 12
7’ 12 13 12 10 10 10
8’ 10 10 10 8 8 8
9’ 8 8 8 6 6 6
Units 3 Feet From Wall
Units 2 Feet From Wall
25˚25˚
45˚45˚
Candlepower Curve
120W PAR38 WFL
Report 1043FR
Efficiency = 43.5%
Down Wall
Distance From Ceiling, Ft.
Distance From Ceiling, Ft.