Lighting Systems Baselyte-BSL28
Page 2 of 8 4 Light T5 HO Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101635
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 91.9%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 4753 4753 4753 4753 4753
175 4727 4734 4754 4768 4772
165 4551 4597 4697 4773 4801
155 4226 4332 4551 4736 4804
145 3764 3947 4334 4628 4725
135 3171 3471 4019 4344 4447
125 2475 2936 3521 3757 3854
115 1707 2311 2750 2903 2961
105 903 1417 1703 1648 1684
95 181 305 410 312 352
90 3 5 10 7 12
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 74 74 74 51 51 51
1 76 72 69 65 62 60 44 42 41
2 66 61 56 56 52 49 38 36 34
3 58 51 47 49 44 40 34 31 28
4 51 44 39 43 38 34 30 26 24
5 45 38 33 38 33 29 26 23 20
6 40 33 28 34 29 24 23 20 17
7 36 29 24 31 25 21 21 17 15
8 32 25 21 27 22 18 19 15 13
9 29 23 18 25 20 16 17 14 11
10 26 20 16 22 17 14 15 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
17097
17097
0 0
100.0
100.0
0
91.9
91.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 74 74 74 51 51 51
1 76 72 69 65 62 60 44 42 41
2 66 61 56 56 52 49 38 36 34
3 58 51 47 49 44 40 34 31 28
4 51 44 39 43 38 34 30 26 24
5 45 38 33 38 33 29 26 23 20
6 40 33 28 34 29 24 23 20 17
7 36 29 24 31 25 21 21 17 15
8 32 25 21 27 22 18 19 15 13
9 29 23 18 25 20 16 17 14 11
10 26 20 16 22 17 14 15 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
17097
17097
0 0
100.0
100.0
0
91.9
91.9
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.